RaceGrade 60PSIA DTM Pressure Transducer
These sensors feature a built in Deutsch DTM-3P connector on the sensor, making for a very compact and tidy package for all applications. The sensor has a built in -3AN male fitting to quickly install into your setup's needs.
PERFORMANCE SPECIFICATIONS
Ref. Condition 21°C ±1°C (72°F ±2°F)
- Accuracy: Total Error Band includes combined effects of temperature, non-linearity (Terminal Point Method), hysteresis, non repeatabilty, zero offset and span setting errors
±1% of Span: From –20 to 85ºC (–4 to 185ºF)
±1.5% of Span: From –40 to –20ºC (–40 to –4ºF)
±1.5% of Span: From 85 to 125ºC (185 to 257ºF)
Note: Static accuracy ±0.25% of span BFSL (Best Fit Straight Line Method); includes non-linearity, hysteresis and non-repeatable effects at reference temperature 72°F (21°C)
- Stability: Less than ±0.25% span/year
- Durability: Tested to 50 million cycles
ENVIRONMENTAL SPECIFICATIONS
- Temperature: Compensated –40 to 125°C (–40 to 257°F) Operating –40 to 125°C (–40 to 257°F) Storage –40 to 125°C (–40 to 257°F)
- Humidity: 0 to 100% R.H., no effect
FUNCTIONAL SPECIFICATIONS Select from over 25 pressure ranges starting at 30 psi and running through 20,000 psi gauge. Compound (vacuum & pressure) ranges are also available, see “To Order” on back.
- Overpressure (F.S.): Proof Burst
750 psi & below 200% F.S. 1000% F.S.
1500 psi 200% F.S. 500% F.S.
3000 psi 200% F.S. 500% F.S.
5000 psi 150% F.S. 500% F.S.
7500 psi 120% F.S. 500% F.S.
10,000 psi 120% F.S. 240% F.S.
20,000 psi 120% F.S. 240% F.S.
- Vibration: Random vibration (20 g) over temperature range (–40° to 125°C). Exceeds typical MIL. STD. requirements \
- Shock: 100gs, 6 ms
- Drop Test: Withstands 1 meter on concrete 3 axis
- Response Time: Less than 1 msec
- Warm-up Time: Less than 500 msec typical
- Position Effect: Less than ±0.01% span, typical
Reverse Polarity & Miswired Protected: Yes
Insulation Breakdown Voltage: 100 Vac
Insulation Resistance: Greater than 100 megohms at 100 Vdc